The crown jewel

Why your score is what it is

Most commercial owners assume their rating describes their building. Often it describes what could not be proved about their building on the day – and those are not the same thing.

Assumed
recorded in the absence of evidence
Observed
the assessor saw it and recorded it
Measured
tested or calculated, and documented
Not rated
outside the scope of the assessment

Three kinds of input

Every figure on a non-domestic EPC falls into one of three categories, and the certificate does not tell you which is which.

How to read your own certificate's inputs
CategoryWhat it meansCan it be improved without works?
Measured or documentedA tested or calculated value backed by paperwork – an air permeability certificate, a U-value calculation, a commissioning recordNo – it is already the real value
ObservedThe assessor could see it and recorded what they saw – glazing type, luminaire count, visible plantSometimes, if what was visible understated what is there
Assumed (a default)Nothing could be seen and nothing was produced, so a published age-band default was enteredYes – this is the opportunity
The line that matters Evidence can replace an assumption without any work being done to the building. A wall that was always insulated but was recorded as an unknown solid wall is not a building problem. It is a paperwork problem, and paperwork is very much cheaper than insulation.

Where defaults get recorded

These are the inputs that most often carry an assumption on a commercial building, in rough order of how much they tend to cost.

Common assumed inputs on non-domestic assessments
InputThe default when nothing is evidencedWhy it is usually wrong
Air permeabilityA cautious default leakage rate for an untested buildingBuildings constructed or refurbished under recent Part L were tested – the certificate exists, often in the O&M manual
Wall constructionAge-band U-value for an unknown build-up, assumed uninsulatedCavity fill, refurbishment insulation and dry-lining are all invisible from the outside
Roof insulationAge-band default, or the minimum implied by the build dateLoft top-ups and warm-roof refurbishments are rarely documented on site
GlazingAge-band assumption on frame and glass performanceLater replacement units frequently outperform the age assumption
LightingGeneric luminaire efficacy and no credit for controlsAn LED replacement programme with a schedule and product data is one of the biggest single gains
Heating and cooling efficiencyDefault seasonal efficiencies for the plant type and ageManufacturer data and commissioning certificates give the actual figures
ControlsNo credit for controls that cannot be demonstratedA BMS with zoning, optimum start and compensation earns credit only if it is shown to the assessor

What an assumption costs you

Take a 1980s office of 1,800 m² rated D at 84 points, where the walls were recorded as unknown-construction cavity, no air test was available, and the lighting was entered generically.

The cavity was filled during a 2006 refurbishment; the invoice is in the client's files. An air test was carried out after a 2019 recladding; the certificate is in the O&M manual. The lighting was relamped to LED in 2022, and the contractor's schedule lists every fitting.

None of that was available on the day of the assessment, so none of it is in the model. The building is rated for a wall it does not have, a leakage rate it does not suffer and lighting it no longer uses. It has not been mis-assessed – it has been under-evidenced, and the remedy is a folder rather than a contractor.

This is not a trick and it is not a re-rating service We are not describing a way to argue a better number out of an assessor. We are describing the difference between a model told nothing and a model told the truth. If the wall really is uninsulated, evidence will confirm that and the rating will not move.

What overturns each assumption

Evidence that replaces an assumption
Assumption on the certificateThe document that settles it
Unknown wall constructionConstruction drawings, the specification, a cavity-fill guarantee or invoice, or an opening-up record
Unknown roof build-upAs-built details, refurbishment specification, or a measured insulation depth with photographs
Default air permeabilityThe air permeability test certificate
Generic lightingThe lighting schedule with luminaire and lamp data, and the controls specification
Default boiler or chiller efficiencyManufacturer performance data and the commissioning certificate
No credit for controlsBMS schematics, points list, and the controls commissioning record
Default ventilation performanceSpecific fan power data and AHU commissioning sheets
Unknown glazingWindow schedule, or the supplier's U-value and g-value data

Assembling these is the subject of the evidence pack.

The honest limits

  • This only works where an assumption was actually made. A well-evidenced certificate has little headroom, and that is a good outcome to discover cheaply.
  • Evidence has to be genuine and contemporaneous. Reconstructing it after the fact is not the same thing, and an assessor will not accept it.
  • SBEM publishes no per-measure point value, so nobody can honestly promise you a specific number of points from a specific document in advance. We give indicative ranges and say plainly that they are indicative.
  • It may confirm bad news. Sometimes the default was generous.

Find out how much of your rating is assumption

We read the certificate on the register, identify which inputs carry defaults, and tell you what evidence would settle each one – before you spend anything on works.

Common questions

Can my EPC rating improve without doing any work?

Yes. Where the assessor recorded a default because no evidence was available, supplying that evidence at a re-assessment replaces the assumption with the real value. Nothing about the building changes; the model's description of it does.

Why would an assessor assume the worst?

Because the conventions require it. An assessor may only enter what they can see or evidence. Where construction is concealed and no documentation is offered, published age-band defaults are used, and those defaults are deliberately cautious.

Would a different assessor give me a better rating?

Not on the same evidence. Two competent assessors given the same information should reach materially the same result. The variable is the information, not the assessor.

How much difference can evidence make?

It varies with the building. The largest movements we see come from air permeability testing, lighting schedules and construction records on buildings where the walls were recorded as unknown.

Sources

Legislation is cited to the version in force at the date below. We publish a corrections policy and amend pages when the law changes.

Written and reviewed by the evenEco assessment team Last updated Figures from the GOV.UK Energy Performance of Buildings Register, non-domestic extract for England & Wales, analysed 11 September 2026 How we produce this